Fourth order Linkwitz-Riley active filter
LR4 Crossover Designer
Two cascaded 2nd order Butterworth sections per output. The low-pass and high-pass are each -6 dB at crossover and sum flat with matched polarity.
Order
4th
Slope
24 dB/oct
Q per biquad
0.707
Magnitude Response
Log-frequency plot in dB.
Low-pass
High-pass
Sum
Phase Response
Unwrapped electrical phase in degrees.
Move over a plot
Analog Schematic
Cascade the shown section twice for low-pass and twice for high-pass.
Low-pass 2nd order section
Use twiceHigh-pass 2nd order section
Use twice
Equal R and equal C are shown as a practical starting point for the ideal LR4 target above. Branch gain
defaults to unity and can be raised when you need makeup gain or level matching across the two cascaded
filters. Use tight-tolerance matched parts for best acoustic summing.